Overview
- Support functions for Comblock assembly:
- DC/DC converter for extended supply range
- RS422 interface for longer cable connections
- 40 MHz clock as reference processing clock for FPGAs
- Signal conditioning for easer interfacing with binary streams (data/clock)
- DC/DC converter:
- Input supply: 6 – 26V
- Vcc1 output: 5V 2.5A max
- Vcc2 output: 5V 2.5A max
- Reverse voltage protection
- Resettable fuse
- RS-422:
- 4 differential input signals
- 4 differential output signals
- RS-232:
- 1 full duplex link for monitoring & control
- Connectorized:
- DB25 on user side
- Two standard 40-pin 2mm dual row connectors on the ComBlock sides
- COM-1800 FPGA development platform
Documentation
Latest firmware
FPGA latest configuration .bit file